Home  |  Career  |  Webmail Login  |  Sitemap  |  Contact Us
 
 
MAN Turbo India
 
  Home
  Company
Products
  Services
  News
  Downloads
 
    Compressors
    Expanders
  Turbines
 
Print Send

 

 

Turbine
FT8-Gas Turbine Back  
The FT8 gas turbine is based on modern aeroengine technology from Pratt & Whitney, adapted for industrial use. The gas turbine is characterised by a compact, modular design. FT8 gas turbines achieve a high level of availability and are extremely reliable.

The PowerPac and the TwinPac offer two different variants of the FT8 gas turbine for power generation purposes. To drive compressors MechPac the power turbine developed by MAN Turbo is used.
 
This has a rated speed of 5500 rpm. Pollutant emissions are reduced by means of Dry-Low-NOx-Brennkammer or by injecting water into the fuel chamber of the turbine.Power turbines for driving generators:
  • Speed of 3,000 rpm, no gear unit, coupled directly to a generator for 50 Hz
  • Speed of 3,600 rpm, no gear unit, coupled directly to a generator for 60 Hz
  • Both power turbines are available both with clockwise and anti-clockwise rotation.
Power turbine for mechanical drive:
  • Speed of 5,500 rpm, speed range variable between 2,500 – 5,750 rpm, counterclockwise (in flow direction).

The FT8 gas turbine is used for:

Mechanical drives:
  • Compressors
Generator applications:
  • Combined heat and power stations (CHP)
  • Power stations
 

FT8 PowerPac

FT8 TwinPac

FT8 MechPac

Mechanical drive

Power at coupling

kW

-

-

25,980

 

hp

-

-

34,840

Thermal efficiency level

%

-

-

38.6

Heat consumption

kJ / kWh

-

-

9,329

 

Btu / hph

-

-

6,593

Generator drive

 

Btu / hph

-

-

6,593

Terminal power

kW

25,490

51,350

-

Electrical efficiency level

%

38.1

38.4

-

Heat consumption

kJ / kWh

9,442

9,380

-

 

Btu / kWh

8,950

8,890

-

 

 

 

 

 

Exhaust gas parameters

Exhaust gas temperature

°C

457

457

457

 

°F

855

855

855

Exhaust gas mass flow

kg / s

85

85

85

 

lb / s

187

187

187

 

 

 

 

 

Speed, power turbine

 

min-¹

3,000/3.600

3,000/3.600

5,500

Leistungskurven

 

 

display

display

display

For all data: 15°C (59°F), sea level (101.3 kPa), zero inlet and exhaust pressure losses, rel. humidity 60 %, fuel: natural gas, no water injection

 
 
 